Honestly without seeing it in person i wouldn t be all gung ho about bypassing it.
Can you bypass a pressure switch on a gas furnace.
Make sure the hose is not obstructed inside.
This might free the switch from sticking.
You can however test with a continuity tester testing with pump off and then pump on.
By this point on an 80 efficiency furnace if you haven t found the culprit you will have to put on your best thinking cap because the issue could be any number of things including a bad board loose or bad wire connections or a bad pressure switch.
If you are working on a 90 condensing furnace move to the condensate drain.
If a pressure switch is not jumpered correctly the furnace will not turn on at all.
How to jump or bypass pressure switch on a furnace.
On newer furnaces on a call for heat the ifc checks the pressure switch.
With pump on should be closed allowing continuity.
As long as the induced draft blower runs and there isnt a blockage in the flue then you should be fine.
When you do this you should hear a clicking noise.
So go ahead and put the hose back on put the access panel back on the furnace turn up the thermostat to its highest setting.
Take off the end so you can blow through it to the pressure switch.
After all this the furnace should fire right back up.
In no way do i recommend you attempt bypassing switch and should only be done by qualified technician.
Now use the ohmmeter to check whether the pressure switch is functioning properly.
Remove the pressure switch hose s after carefully noting where it is connected if there is more than one hose remove and reinstall them one at a time.
Suck on the power hose and then check the switch again using the ohmmeter.
If you get a pressure switch code and the inducer will not come on remove one of the wires from the pressure switch.
The pressure switch on a lennox g16 gas furnace monitors whether the air blower is in operation.
It doesn t take much pressure so don t blow too hard.
Sometime the switch itself the part buried within can fail.
This would only be d.
If your lennox does not activate normally during the ignition sequence try running a quick bypass of the pressure switch to determine if it is the problem.
First turn the power of the furnace off.
The switch activates with air force pushing a plunger in the mechanism which closes the circuit.